$649.00

The QuadProcess is a four channel, battery powered, stand alone low level DC current data logger. The Device records time and date stamped DC current data from external sensors, transducers and many other sources.

The data logger features user-programmable Engineering Units and offset/gain calculations so input signals can be scaled to proper units being measured. For example, a water meter with a 4-20 mA output can be displayed as liters or gallons, etc., in the software graph and data. Negative current signals can be monitored and recorded, for a broad range of applications.

Three different DC current ranges are available ±1 mA, ±25 mA or ±100 mA. The QuadProcess can measure and record data for up to 32,767 readings per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. The QuadProcess makes data retrieval quick and easy. Simply plug it into an empty COM or USB port and our user-friendly software does the rest.


CURRENT

Current Range ±1 mA, ±25 mA, ±100 mA
Current Resolution ±1 mA: 0.05 μA
±25 mA: 1 μA
±100 mA: 5 μA
Current Calibrate Accuracy ±1 mA: ±0.5 %FSR at 25 °C (77 °F)
±25 mA and ±100 mA: ±0.1 %FSR at 25 °C (77 °F)
Current Input Impedance ±1: 50 Ω
±25 mA: 10 Ω
±100: 2 Ω

GENERAL

Memory 32,767 readings per channel
Reading Rate 1 reading every second up to 1 reading every 12 hours
Baud Rate 2,400
Channels 4
LED Indicators None
Battery Life 1 year
Material Anodized aluminum
Dimensions 3.5 in x 4.4 in x 1.0 in (89 mm x 112 mm x 26 mm)
Operating Environment -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
Required Interface Package IFC110 or IFC200

Nominal Range ±1 mA ±25 mA ±100 mA
Measurement Range ±1.5 mA ±30 mA ±120 mA
Input Range 0 to 2.5 V
Resolution 0.05 μA 1 μA 5 μA
Calibrated Accuracy
at 25 °C (77 °F)
±0.5 %FSR at 25 °C (77 °F) ±0.1 %FSR at 25 °C (77 °F)
Input Imedence 50 Ω 10 Ω 2 Ω

Click and Drag to Rotate